IPB Series(220/230/240VAC) 500~3000W Pure Sine Wave Inverter
IPB series pure sine wave inverter with utility bypass function ensures stable, efficient power supply in off-grid solar systems.
EPEVER IPB series pure sine wave inverter is a high-frequency inverter with a utility bypass function, meeting the requirements of inverter output or bypass power supply. The advanced voltage-current dual closed-loop control algorithm achieves precise power control, enhancing the stability and efficiency of the inverter. IPB series features fast response, high conversion efficiency, and low Total Harmonic Distortion(THD). It can be applied in DC-AC solar off-grid systems. You can enjoy reliable power in your house, RV, or outdoor camping with EPEVER IPB anywhere, anytime.
Parameter | IPB500-12 | IPB1000-12 | IPB1500-12 | IPB2000-12 | IPB3000-12 |
AC Input Voltage Range | 190~265VAC | ||||
Fast-acting Fuse① Rated Current | 3A | 5A | 8A | 10A | 15A |
AC Input Frequency Range | 45Hz~55Hz/55Hz~65Hz | ||||
Battery Rated Voltage | 12VDC | ||||
Battery Work Voltage Range | 10.8 ~ 16.0VDC | ||||
Battery Rated Input Current | 46.7A | 92.3A | 141.1A | 185.6A | 283.7A |
Continuous Output Power | 500W@35℃@Battery Rated Voltage | 1000W@35℃@Battery Rated Voltage | 1500W@35℃@Battery Rated Voltage | 2000W@35℃@Battery Rated Voltage | 3000W@35℃@Battery Rated Voltage |
5-second Transient Surge Output Power | 1000W | 2000W | 3000W | 4000W | 6000W |
Inverter Output Voltage | 220VAC (±3%); 230VAC (-6%~+3%); 240VAC (-9%~+3%) | ||||
Inverter Frequency | 50/60Hz ± 0.2% | ||||
Output Voltage Waveform | Pure Sine Wave | ||||
Output Voltage Harmonic Distortion Rate | ≤ 3% (Resistive load) | ||||
Load Power Factor | 0.2 ~ 1 (Load power ≤ Continuous output power) | ||||
Maximum Output Current | 4.6A | 9.2A | 13.8A | 18.4A | 27.6A |
Rated Output Current | 2.3A | 4.6A | 6.9A | 9.2A | 13.8A |
Rated Output Efficiency② | 90.20% | 91.40% | 89.70% | 90.90% | 89.20% |
Maximum Output Efficiency③ | > 91.0% (40% loads) | > 93.0% (40% loads) | > 93.0% (30% loads) | > 94.0% (30% loads) | > 94.0% (30% loads) |
Idle Current | < 0.15A | < 0.2A | < 0.2A | < 0.2A | < 0.2A |
No-load Current | < 0.9A | < 1.1A | < 1.2A | < 1.2A | < 1.6A |
RS485 Communication Port | 5VDC/200mA | ||||
Mechanical parameters | |||||
Input Terminal | M6 | M10 | |||
Dimension (Length x Width x Height) | 335 × 160 × 73mm | 371 × 228 × 118mm | 387 × 228 × 118mm | 420 × 228 × 118mm | 545 × 228 × 118mm |
Mounting Size (Length x Width) | 311 × 75mm | 345 × 145mm | 361 × 145mm | 395 × 145mm | 520 × 145mm |
Mounting Hole Size | Φ5mm | Φ6mm | Φ6mm | Φ6mm | Φ6mm |
Net Weight | 2.3kg | 4.8kg | 6.0kg | 7.0kg | 9.5kg |
Environment parameters | |||||
Work Temperature Range | -20℃ ~ +60℃ (Refer to the Derating Curve) | ||||
Storage Temperature Range | -35 ℃ ~ +70 ℃ | ||||
Relative Humidity | ≤ 95% (N.C.) | ||||
Enclosure | IP20 | ||||
Altitude | < 5000m (If the altitude exceeds 1000 meters, the rated power will be reduced according to IEC62040.) |
① For details about the Fast-acting fuse, see instructions on the terminal ❾ in chapter 2 of the manual, Appearance.
② It means the rated output efficiency when the load power equals the "continuous output power" under the battery-rated voltage.
③ It means the maximum output efficiency when the inverter is connected to different loads under the battery-rated voltage.
Datasheet
EPEVER-Datasheet-IPB
Manual
IPower-Manual-EN
Product Highlights
Pure sine wave output
Input to output electrical isolation
Utility bypass automatic switching function (utility supplies load when the utility is normal)
Output power factor up to 1
Input Protection: Low-voltage, Over-voltage
Output Protection: Overload, Short circuit, Overheating
RS485 com. port to realize remote monitoring
External switch design, matched with EPEVER products, to expand inverter control function and reduce power consumption