iTracer-ND Series(60A) MPPT Charge Controller
with 60A discharge current
IT6415ND charge controller with 60A DC output current adopts advanced Maximum Power Point Tracking (MPPT) algorithm, which can harvest the maximum power from the solar array to
charge the battery. It is capable of supporting up to 800W PV power in 12V system, 1600W in 24V system,2400W in 36V system, and 3200W in 48V system.
Model | IT6415ND |
Nominal system voltage | 12/24/36/48VDC |
Battery type | Sealed(Default)/Gel/Flooded/User |
Battery input voltage range | 8~68V |
Rated charge current | 60A |
Rated discharge current | 60A |
Max. conversion efficiency | ≤98.0% |
Tracking efficiency | ≥99.5% |
Max. PV open circuit voltage | 150V( At minimum operating environment temperature) 138V(At 25℃ environment temperature) |
MPP voltage range | (Battery voltage+2V)~108V |
Rated charge powe | 800W/12V;1600W/24V;2400W/36V;3200W/48V |
Equalization voltage | Sealed:14.6V,Flooded:14.8V,User-defined:9-17V |
Boost voltage | Gel:14.2V,Sealed:14.4V,Flooded:14.6V,User-defined:9-17V |
Float Voltage | Gel/Sealed/Flooded:13.8V,User-defined:9-17V |
Low voltage reconnect voltage | Gel/Sealed/Flooded:12.6V,User-defined:9-17V |
Low voltage disconnect voltage | Gel/Sealed/Flooded:11.1V,User-defined:9-17V |
Self-consumption | 1.4W~2.6W |
Temperature compensation | -3mV/℃/2V (Default) |
Relative humidity | ≤95%, N.C. |
Enclosure | IP20 |
Communication port | RS485, RS232 |
Grounding | Common Negative |
Operating temperature range | - 25℃~+50℃ |
Dimensions(LxWxH)mm | 440×231×110 |
Net weight | 5.9kg |
Datasheet
EPEVER-Datasheet-iTracer-ND
Manual
iTracer-ND-Manual-EN-V4.3
Certificates
Certificate FCC iTracer-ND
Certificates
Certificate EMC iTracer-ND
Certificates
Certificate ROHS iTracer-ND
Certificates
Certificates IEC iTracer-ND
Product Highlights
MPPT tracking efficiency above 99.5%
Maximum charge conversion efficiency as high as 98%
Battery type selection: Sealed, Gel, Flooded and User(programmable)
Multiphase sychronous rectification technology (MSRT)
60A DC load output current
Remote monitoring function
Data-log function, recording system running information and event
Die cast aluminum case design
Extensive electronic protections
IEC62109 certified
With RS-485, RS-232 communication bus interface and Modbus communication protocol
IT6415ND charge controller has the function of recording the running states and events, but these records would be lost when the unit is powered off if no button cell is installed. If the records are not desired, no button cell is required.