UPower-HI Series(110/120VAC) 2000~3000W Inverter/Charger
UPower-Hi series is an inverter charger that supports diversified energy management modes on solar/utility/generator charging, and utility/inverter power supply to the AC loads.
UPower-Hi series is an inverter charger that supports diversified energy management modes on solar/utility/generator charging, and utility/inverter power supply to the AC loads. To maximize solar energy utilization, users can choose energy sources according to actual needs and flexibly take the utility as a supplement. This inverter charger can raise the system's power supply guarantee rate, which is suitable for solar energy, utility/oil generator hybrid systems. It aims to provide users with high-quality, high-stability, and high-reliability electrical energy.
Item | UP2000-HM6021 | UP3000-HM10021 | UP3000-HM5041 | UP3000-HM8041 |
Rated battery voltage | 24VDC | 48VDC | ||
Battery input voltage | 21.6~32VDC | 43.2~64VDC | ||
Max. battery charging current | 60A | 100A | 50A | 80A |
Inverter output | ||||
Continuous output power | 2000W | 3000W | 3000W | 3000W |
Max. surge power(3S) | 4000W | 6000W | 6000W | 6000W |
Output voltage range | 110VAC(-3%~+3%), 120VAC(-10%~+3%) | |||
Output frequency | 50/60±0.2% | |||
Output wave | Pure Sine Wave | |||
Load power factor | 0.2-1(Load power ≤ Continuous output power) | |||
Distortion THD | THD≤5%(Resistive load) | |||
80% rated output efficiency | 89% | 90% | 91% | 91% |
Max. Rated output efficiency | 88% | 88% | 90% | 90% |
Max. output efficiency | 90% | 92% | 92% | 92% |
Switch time | 10ms(Switch from the utility output to the inverter output), 15ms(Switch from the inverter output to the utility output) | |||
Utility charging | ||||
Utility input voltage | 88VAC~132VAC (Default), 80VAC~140VAC(Programmable) | |||
Utility input frequency | 40~65Hz | |||
Max. utility charge current | 60A | 80A | 40A | 40A |
Solar charging | ||||
Max. PV open circuit voltage | 250V(At minimum operating environment temperature), 220V(At 25℃ environment temperature) | |||
MPPT voltage range | 60~200V | |||
Max. PV input power | 2000W | 3000W | 3000W | 4000W |
(Note: For the curve of Max. PV input power Vs. PV open-circuit voltage, see chapter 3.4 Operating mode for details.) | ||||
Max. PV charging power | 1725W | 2875W | 2875W | 4000W |
Max. PV charging current | 60A | 100A | 50A | 80A |
Equalize charging voltage | 29.2V(AGM default) | 58.4V(AGM default) | ||
Boost charging voltage | 28.8V(AGM default) | 57.6V(AGM default) | ||
Float charging voltage | 27.6V(AGM default) | 55.2V(AGM default) | ||
Low voltage disconnect voltage | 21.6V(AGM default) | 43.2V(AGM default) | ||
Tracking efficiency | ≥99.5% | |||
Temp. compensate coefficient | -3mV/℃/2V(Default) | |||
General | ||||
Surge current | 50A | 60A | 56A | 95A |
Zero load consumption | <1.6A | <1.6A | <1.2A | <0.8A |
(without PV and utility connection, turn on the load output) | ||||
Standby current | <1.2A | <1.0A | <0.7A | <0.6A |
(without PV and utility connection, turn off the load output) | ||||
Mechanical Parameters | ||||
Dimension(H x W x D) | 607.5x381.6x127mm | 642.5x381.6x149mm | 642.5x381.6x149mm | 642.5x381.6x149mm |
Mounting size | 585*300mm | 620*300mm | 620*300mm | 620*300mm |
Mounting hole size | Φ10mm | Φ10mm | Φ10mm | Φ10mm |
Net Weight | 15kg | 19kg | 19kg | 19kg |
Enclosure | IP30 | |||
Relative humidity | < 95% (N.C.) | |||
Environment temperature | -20℃~50℃ |
Datasheet
EPEVER-Datasheet_UP-HI_110V
Manual
UPower-Hi-Manual-EN-V2.6
Certificates
CE Verification UP-HI
Certificates
Certificate EN UP-HI
Certificates
Certificate IEC UP-HI
Certificates
Test Report RoHS UP-HI
Product Highlights
Supports the battery mode or non-battery mode
Surge current and reverse connection protections to support the lithium battery system perfectly
Three charging modes: Solar only, Solar priority, Utility & Solar
Two AC output modes: Utility priority and Inverter priority
High tracking efficiency of MPPT no less than 99.5%
PFC technology which achieves a high power factor of AC to DC charging and reduces the usage of power grid capacity
Advanced SPWM technology and pure sine wave output
Configurable battery charging current and discharging current
Self-learning SOC function
Configurable grid charging current
4.2 inch LCD to monitor and modify system parameters
Optional WiFi or GPRS Remote control by the RS485 isolated communication port
BMS-Link port and optional BMS-Link communication protocol module
Yes. The inverter can work with a lithium battery without communicating with BMS. However, the real-time monitoring data and protection point will be the sampling data from the inverter. But the user has to set the voltage setpoints of the inverter according to the data of the BMS, or it will cause the charging abnormal.
EPEVER Admin 13 July 2021
Yes, it has no No-Battery mode. The parameters can be set without a battery connection.
EPEVER Admin 13 July 2021
Yes.
This series can not only set the total charging and discharging limiting current of the battery but also set the charging current of the utility. Users can flexibly configure the utility according to the demand.
EPEVER Admin 13 July 2021
solar inverter prices online –